Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 10 patents, you can check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (24)
  • Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer
  • Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer
  • Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer
  • Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer
  • Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer
  • Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
AG-NMHC07
Brand
Juge
Customized
Customized
Portable
Non Portable
Certification
CE
Gas
Nmthc
Type
Catalytic Oxidation+Fid
Nmthc Range
0-200mgc/M3 OEM
Repeatability
Less Than 1%
Linearity Error
Less Than 1%F.S
Analyzer Heating
120 Celsius
Analysis Cycle
Less Than 10s
Catalytic Efficiency
More Than 98%
CH4 Retention Rate
More Than 98%
Transport Package
Carton
Specification
5U
Trademark
JUGE or OEM
Origin
Nanjing, China

Product Description


Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer
Product Description
Flue Gas Analyzer CEMS Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer

>>Overview

The AG-NMHC07 Analyzer is a non-methane hydrocarbon (NMHC) emission monitoring system based on catalytic oxidation and flame ionization detection (FID) principles. It provides real-time measurement of total hydrocarbons (THC) and non-methane hydrocarbons (NMHC) concentrations in industrial flue gases. This analyzer is designed for monitoring organic compound emissions from stationary pollution sources across industries such as petrochemicals, chemical manufacturing, industrial coating, packaging/printing, rubber products, electronics, organic solvent production, automotive manufacturing, pharmaceuticals, and others.


>>Feature

1. Full thermal method with high-temperature analysis throughout the process, effectively preventing sample loss and ensuring accurate and reliable monitoring data;
2. Fast response speed, short analysis cycle, and real-time data output;
3. Simple and quick calibration operation, with calibration time as short as 30 seconds;
4. Compliant with international standards and Chinese national standard HJ1013-2018;
5. 5U standard chassis design for easy integration;
6. Integrated high-temperature pump in the analyzer, supporting direct connection via heated tubing;
7. No carrier gas required;
8. Simultaneous monitoring of NMHC, THC, and CH4;
9. Automatic ignition and hydrogen cutoff after flame extinguishment, ensuring safety and reliability;


>>Technical Parameter
 
Manufacturer JUGE Model AG-NMHC07
Parameter NMHC, THC, CH4 Size 500mm×482(435)mm×213mm  (L×W×H)
Range
NMHC:(0-200)mgC/m3
 
Weight
25.2kg
Detect limit 0. 1mg/Nm3 Working environment (5~40)ºC    (0~95)%RH
Analyzer Heating 120ºC Sample gas 80kPa- 110kPa
Catalytic Temperature 200ºC Hydrogen Supply Purity: ≥99.99%
Source: Hydrogen cylinder or hydrogen generator
Pressure: 0.2 MPa
Repeatability ≤ 1% Air Supply Clean air, hydrocarbon concentration ≤0.3 mg/m³
Pressure: 0.4 MPa
Analysis Cycle ≤ 10s(, 300s) Drive gas Dehumidified, dust-free, oil-free compressed air
Pressure: 0.4 MPa
Zero Point Drift, Span Drift ≤±2%F.S./24h Calibration Gas   Methane/propane single-component or mixed standard gas
Pressure: 0.2 MPa
Linear Error ≤±1%F.S. Power supply 220 VAC ,50Hz
Catalytic Efficiency ≥98% Power Consumption 500w , 150W
CH4 Retention Rate ≥98% Communication Protocol Modbus 
Company Profile

Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer
>>OEM Solutions & Service Advantages
We provide OEM customization services. Contact us to discuss tailored product solutions. 

1) 12-hour response guarantee for all inquiries;
2) Premium quality with industry-competitive pricing;
3) Dedicated post-purchase support system;
4) OEM/ODM compatibility;
5) Certified safety equipment specialists with expert engineering team.

 

>>FAQ
Q: Can I request a single sample unit for quality assessment?
A: Absolutely. We strongly advise sample evaluation before mass ordering.

 

Q: Could I obtain your product catalog and MOQ pricing details?
A: Our complete product portfolio is available digitally. Please browse our website for model specifications or email specific requests.

 

Q: What pricing advantages apply for large quantity orders?
A: Submit your complete requirements (product model, quantities, quality standards, branding specifications, payment terms, and logistics details) for optimized bulk pricing.

 

>>Certifications
Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer>>Shipping
Flue Gas Analyzer Cems Vocs Waste Gas Non-Methane Total Hydrocarbon Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier