OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 10 patents, you can check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (24)
  • OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector
  • OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector
  • OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector
  • OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector
  • OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Brand
Juge
Customized
Customized
Portable
Non Portable
Certification
CE
Gas
OEM
Alarm
Light & Sound
Resolution
0.1%Lel
Response Time
≤20s (T90)
Accuracy
≤±3% (Depends on Sensor)
Zero Drift
≤±1% (F.S/Year)
Linearity Error
≤±1% (F.S/Year)
Recovery Time
≤20s
Repeatability
≤±1%
Protection Level
IP65
Transport Package
Cartoon
Specification
230*210*90mm with light
Trademark
JUGE
Origin
China

Product Description


OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector
Product Description
OEM CH4 O2 H2S CO CO2 NH3 H2 Cl2 O3 NO NO2 Single Gas Fixed Alarm Detector
 
>>Overview

Equipped with original imported intelligent gas sensors, this is a high-performance intelligent detection instrument capable of continuous online monitoring of multiple gases. The detector features an integral explosion-proof structure with high sensitivity and precision. Real-time gas concentration data can be displayed on a computer through a gas alarm controller and monitoring software. Additionally, optional wireless modules enable real-time transmission of monitoring data and alarm statuses to safety control centers. It is widely applicable across industries such as petroleum/petrochemicals, metallurgy, environmental protection, gas, fire safety, municipal services, chemical engineering, shipbuilding, power generation, process control, wastewater treatment, and emergency rescue monitoring.
 

>>Features
○ Original imported high-performance sensors with high measurement accuracy, excellent repeatability, and long service life.
○ 16-bit AD chip and 4-layer PCB design ensure enhanced weak signal processing and superior anti-interference capabilities.
○ Dashboard-style display interface with clear, elegant readings and user-friendly design details.
○ Multiple unit options: mg/m³, ppm, VOL, and LEL.
○ Embedded 32-bit low-power processor paired with proprietary signal processing algorithms for fast response speed and high stability.
○ Auto-protection against high-concentration gas impact, factory reset function, and misoperation prevention.
○ Built-in infrared remote control for easy operation without opening the housing.
○ Configurable outputs: three-wire 4-20mA, RS485 signal, and relay output.
○ Dual cable entry ports for convenient on-site installation.
○ Robust mechanical design: Gas chamber made of high-grade aluminum alloy profile ensures wear-resistant, corrosion-resistant performance in harsh industrial environments. Scientifically optimized gas chamber design guarantees real-time monitoring accuracy.
○ Explosion-proof certification: Exd II CT6, certified by the National Explosion-Proof Electrical Product Testing Center.
 

>>Main technical parameters

Detect Gas Ex, O2, CO, H2S etc.. OEM
Unit PPM, %LEL, %VOL, mg/m³
Detection Principle

Electrochemical, Infrared, PID etc..

Measurement Range

0-10, 0-100, 0-2000 (customizable ranges available)

Resolution

0.001, 0.01, 0.1, 1

Sampling Method

Free diffusion type - Online continuous detection with free diffusion method.

Installation Method

Wall-mounted; Pipeline-mounted (clamp-on or insertion type; pipeline external thread: M45×1.5mm; optional pipeline adapter screw joints, weldable).

Display Error ≤±3%F.S
Response time ≤20S (T90)
Power supply 12-30VDC
Power Consumption

≤2.5 W (DC24V)

Environmental Pressure

80kPa~120kPa

Environmental Temperature -20ºC~+60ºC (typical), -40ºC~+80ºC (extreme)
(For higher temperature/humidity environments, our preprocessing monitoring system is available).
Environmental Humidity

10%~95%RH (non-condensing)

Explosion-proof

Ex d II CT6 Gb

Protection Rating

IP66

Output Signal

4-20mA; RS485 (customizable options available)

Dimensions

180mm(H) × 140mm(W) × 92mm(D)

Compliance Standards

GB15322.1-2003, GB3836.1-2010, GB3836.2-2010, GB3836.4-2010


>>List of Commonly Detected Gas Types

NO

Detection

Range

Accuracy

T90 Response time

Resolution

Alarm set point (low/high)

1

PH3

0 - 5 ppm

±5% (F.S)

≤ 25 s

0.01 ppm

0.3 ppm/5 ppm

2

O2

0-30%Vol

±5% (F.S)

≤ 15 s

0.10% Vol

18.0%Vol/23.0%Vol

3

EX

0-100% LEL

±5% (F.S)

≤ 15 s

1% LEL

25.0%/50.0% LEL

4

CO

0 - 2000 ppm

±5% (F.S)

≤ 25 s

1 ppm

50 ppm/100 ppm

5

H2S

0 -100 ppm

±5% (F.S)

≤ 30 s

1 ppm

10 ppm/20 ppm

6

SO2

0 - 100 ppm

±5% (F.S)

≤ 30 s

0.1 ppm

2 ppm /10 ppm

7

CI2

0 - 20 ppm

±5% (F.S)

≤ 30 s

0.1 ppm

1 ppm /10 ppm

8

NH3

0 - 200 ppm

±5% (F.S)

≤ 50 s

1 ppm

25 ppm /50 ppm

9

NO2

0 - 20 ppm

±5% (F.S)

≤ 25 s

0.1 ppm

3 ppm/10 ppm

10

NO

0 - 250 ppm

±5% (F.S)

≤ 60 s

1 ppm

25 ppm/50 ppm

11

H2

0 - 1000 ppm

±5% (F.S)

≤ 60 s

1 ppm

50 ppm /100 ppm

12

HCN

0 - 50 ppm

±5% (F.S)

≤ 200 s

0.1 ppm

10 ppm /20 ppm

13

HCL

0 - 20 ppm

±5% (F.S)

≤ 60 s

0.1 ppm

5 ppm /10 ppm

14

CH4

0 - 5% Vol

±5% (F.S)

≤ 60 s

0.1% Vol

customized

15

CO2

0 - 5% Vol (0-5000ppm)

±5% (F.S)

≤ 60 s

0.01% Vol (1 ppm)

customized

16

PID(VOCs)

1-1999 ppm

±5% (F.S)

≤ 20 s

0.1 ppm

customized

17

C3H8

0 - 5%Vol

±5% (F.S)

≤ 60s

0.01% Vol

customize

18

O3

0 - 5 ppm

±5% (F.S)

≤ 30s

0.02 ppm

1ppm/2 ppm

19

SF6

0 - 1000 ppm

±5% (F.S)

≤ 60s

0.2ppm

25ppm/50 ppm

20

HF

0 - 10 ppm

±5% (F.S)

≤ 60s

0.1ppm

3ppm/10 ppm

 
OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector
Company Profile

OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector
>>OEM Solutions & Service Advantages
We provide OEM customization services. Contact us to discuss tailored product solutions. 

1) 12-hour response guarantee for all inquiries;
2) Premium quality with industry-competitive pricing;
3) Dedicated post-purchase support system;
4) OEM/ODM compatibility;
5) Certified safety equipment specialists with expert engineering team.

 

>>FAQ
Q: Can I request a single sample unit for quality assessment?
A: Absolutely. We strongly advise sample evaluation before mass ordering.

 

Q: Could I obtain your product catalog and MOQ pricing details?
A: Our complete product portfolio is available digitally. Please browse our website for model specifications or email specific requests.

 

Q: What pricing advantages apply for large quantity orders?
A: Submit your complete requirements (product model, quantities, quality standards, branding specifications, payment terms, and logistics details) for optimized bulk pricing.

 

>>Certifications
OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector>>Shipping
OEM CH4 O2 H2s Co CO2 Nh3 H2 Cl2 O3 No No2 Single Gas Fixed Alarm Detector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier