Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer

Product Details
Customization: Available
Customized: Customized
Portable: Non Portable
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 10 patents, you can check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (24)
  • Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
  • Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
  • Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
  • Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
  • Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
  • Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
AG-CEMS07
Certification
CE
Gas
So2 Nox
Type
Extract Cold Dry Method+UV Absorption Method
So2 Range
0-200mg/M3 OEM
No Range
0-200mg/M3 OEM
No2 Range
0-200mg/M3 OEM
O2 Range
0-25%
Repeatability
Less Than 2%
Response Time
Less Than 120s
Linearity Error
Less Than 2%F.S.
Transport Package
Carton
Specification
19"x3U
Trademark
JUGE or OEM
Origin
Nanjing, China

Product Description


Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
Product Description
CEMS Online SO2 NO NO2 Continuous Emission Monitoring System Flue Gas Analyzer

>>Overview
It can monitor the real-time concentration of particulate matter and gaseous pollutants in the flue gas emitted from stationary pollution sources (such as boilers, industrialfurnaces, incinerators, etc.), enabling supervision of production and emissions fromthe source.

CEMS (Continuous Emission Monitoring System) generally consists of three basic components: the gaseous pollutant monitoring unit (SO2, NO, NO2), the flue gas parameter monitoring unit (temperature, pressure, flow rate, O2, humidity), and the data acquisition and processing unit.

The sample gas passes through a high-temperature heated pipeline, undergoes dustremoval via atwo-stage filter,and is dehumidified by a two-stage condensation system before directly entering the gas chamber of the analyzer. The gas chamber ishoused within the analyzer and connected to an ultraviolet differential analyzer via ultraviolet optical fibers, achieving accurate measurement of the flue gas.


>>Feature
1) Secondary condensation for rapid water removal, reducing SO2 loss.
2) Long-life UV xenon lamp with high wavelength resolution ensures low detection limits, minimal temperature drift, fast response time, and accurate measurements.
3) PLC-controlled with adjustable parameters to adapt to complex working conditions.
4) Intelligent system design with traceable fault alarms for easy maintenance and troubleshooting.
5) Fully modular design, enabling flexible expansion of monitoring factors.
6) Flexible configuration: Users can choose between an NO2-NO converter or direct NO measurement as required.

>>Main technical parameters
Project Index
Gaseous pollutant So2 (0~200) mg/m3, the range can be customized
No (0~200) mg/m3, the range can be customized
No2 (0~200) mg/m3, the range can be customized
O2 (0~25)%
Repetitiveness ≤2%
24h zero drift and range drift ≤±2%f.s.
One-week zero-point drift and range drift ≤±3%f.s.
Linear error ≤±2%f.s.
Response time ≤120s
Particulate matter Measured range (0.5~15)m
Dust concentration range (0~10) mg/m3, the range can be customized
Accuracy ≤±2%f.s./24h
Flue gas parameters Temperature Measuring range (0~300) ºC, is customizable
Accuracy  
Pressure Measuring range (-10~10)kpa
Accuracy  
Velocity of flow Measuring range (0~40) m/s, (0~2) kpa, the output is optional
Accuracy  
Humidity Measuring range (0~40)vol%
Accuracy  
Data acquisition and processing Data transmission module 8-way analog input 
1-channel rs485 communication interface
IPC 6-way rs232 communication interface
Windows7 operating system
Operational software Flue gas emission monitoring software monitor
Power Supply Ac 220v,50hz,≤7kw

>>System composition
Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas AnalyzerAG-UVA07 Flue Gas Analyzer
Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer

>>Overview
The AG-UVA07 gas analyzer consists of several key components, including a light source, gas chamber, spectrometer, HMI module, interface board, temperature sensor, electrochemical oxygen sensor, and expandable modules. 

The analyzer employs advanced technologies such as Differential Optical Absorption Spectroscopy (DOAS) and Partial Least Squares (PLS) algorithms for spectral data processing. It features a compact and versatile measurement chamber designed for high precision and ease of maintenance. Additionally, the device integrates a high-performance microprocessor with embedded software capable of signal processing, data computation, real-time monitoring, keyboard operations on the HMI, LCD display, alarm functions, and system settings.


>>Feature
1) Multi-pass gas chamber design for extended optical path and ultra-low gas concentration detection.
2) Low drift, high precision, low power consumption, fast response.
3) High-performance UV xenon lamp with long lifespan and vibration-resistant design.
4) Modular design for light source, detector, and core circuit, ensuring high reliability, scalability, and easy maintenance.
 
Company Profile

Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer
>>OEM Solutions & Service Advantages
We provide OEM customization services. Contact us to discuss tailored product solutions. 

1) 12-hour response guarantee for all inquiries;
2) Premium quality with industry-competitive pricing;
3) Dedicated post-purchase support system;
4) OEM/ODM compatibility;
5) Certified safety equipment specialists with expert engineering team.

 

>>FAQ
Q: Can I request a single sample unit for quality assessment?
A: Absolutely. We strongly advise sample evaluation before mass ordering.

 

Q: Could I obtain your product catalog and MOQ pricing details?
A: Our complete product portfolio is available digitally. Please browse our website for model specifications or email specific requests.

 

Q: What pricing advantages apply for large quantity orders?
A: Submit your complete requirements (product model, quantities, quality standards, branding specifications, payment terms, and logistics details) for optimized bulk pricing.

 

>>Certifications
Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer>>Shipping
Cems Online So2 No No2 Continuous Emission Monitoring System Flue Gas Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier