Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 10 patents, you can check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (24)
  • Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
  • Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
  • Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
  • Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
  • Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
  • Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
AG-CEMS08
Brand
Juge
Customized
Customized
Portable
Non Portable
Certification
CE
Gas
HCl Co
Type
Laser Gas Analyzer
Light Path
760mm
Range
0-100 Ppm/Mg/M3
Response Time
Less Than 300S
Repeatability
Less Than 2%
Display Error
Less Than 5%
Drift
Less Than 2.5%F.S
Transport Package
Carton
Specification
(950H*1160L*325W)mm
Trademark
JUGE or OEM
Origin
Nanjing, China

Product Description


Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
Product Description
Waste Incineration CEMS Flue Gas HCl CO Continuous Emission Monitoring System

>>Overview
Designed for the conditions of flue gas after waste incineration, industrial instruments are used for continuous online measurement of SO2, NO, NO2, CO, CO2, O2, NH3, HCl, H2O, flow rate, pressure, temperature, particulate matter, and other components. Additional measurement components can be added according to user requirements.

Mainly applied in domestic and international municipal waste incineration, hazardous waste incineration, medical waste incineration, sludge incineration, biomass boilers, thermal power plants, steel mills, and other high-temperature, high-humidity environments.


>>Feature
1) Self-diagnosis and alarm function.
2) Laser absorption spectroscopy with minimal background interference and fast response.
3) High detection sensitivity and low resolution.
4) Built-in long optical path design to solve interference issues.
5) Low system maintenance cost and minimal maintenance.
6) High structural stability, adaptable to various environments.

>>Main technical parameters
Working condition Power supply 220vac,<3kw
Sweeping gas (0.4~0.6) MPA compressed air
Ambient temperature -20ºC~55ºC
Performance index Light path length 760mm
Range 0~100 (ppm or mg/m3) (range-adjustable)
T90 response time <300 seconds
Reading error ≤ ± 5% (nominal value)
Repeatability ≤ ±2% F.S
Drift ≤ ±2.5% F.S
Protection level Ip55
Preheating time 120min
Functional parameter Digital output RS485
Analog output 4 -20 ma maximum load of 500Ω
Switch output Load capacity: Ac / DC 24V / l A;
Backback signal, low instrument wind pressure, abnormal temperature alarm, etc. (customizable)
Sample gas temperature <600ºC
Other parameters Sample gas pressure Atmospheric pressure of ± 5 KPA
Sampling traffic 2-3l/min
Ambient temperature -10~55ºC
Ambient pressure 70~120kpa
Outline dimension (950h×1160l×325w)mm
Weight 120kg

>>System composition
No. Name Model and specification Quantity Unit
1 Pre-processing cabinet Pre-treatment and control devices 1 Set
1.1 Analysis Cabinet 950H×1160L×325W  mm 1 Set
1.2 Electromagnetic valve DC24v, normally closed 2 Set
1.3 Injection pump 8l/min 1 Set
1.4 High-temperature precision filter 0.2um 1 Set
1.5 Control circuit Including automatic sampling, back-blowing, and temperature control 1 Set
1.6 High temperature cut-off valve BTB-DN10, with a pneumatic valve 1 Set
2 Analytic system HCL, CO analyzer 1 Set
3 Heated-type sampling probe AG-TT07 1 Set
4 Sampling heat tracing pipeline 60w/m 3 Set
5 Spare part See the list of spare parts 1 Set

Company Profile

Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
>>OEM Solutions & Service Advantages
We provide OEM customization services. Contact us to discuss tailored product solutions. 

1) 12-hour response guarantee for all inquiries;
2) Premium quality with industry-competitive pricing;
3) Dedicated post-purchase support system;
4) OEM/ODM compatibility;
5) Certified safety equipment specialists with expert engineering team.

 

>>FAQ
Q: Can I request a single sample unit for quality assessment?
A: Absolutely. We strongly advise sample evaluation before mass ordering.

 

Q: Could I obtain your product catalog and MOQ pricing details?
A: Our complete product portfolio is available digitally. Please browse our website for model specifications or email specific requests.

 

Q: What pricing advantages apply for large quantity orders?
A: Submit your complete requirements (product model, quantities, quality standards, branding specifications, payment terms, and logistics details) for optimized bulk pricing.

 

>>Certifications
Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System>>Shipping
Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier