Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 10 patents, you can check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (24)
  • Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor
  • Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor
  • Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor
  • Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor
  • Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor
  • Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
AG-N08
Display
Digital
Appliance
Water Quality Monitor
Portable
Non Portable
Certification
CE
Type
Ammonia Nitrogen
Range
0-300mg/L OEM
Display Error
5%
Repeatability
Less Than 5%
Measurement Period
30min
Output
RS-232, 4-20mA, RS-485
Transport Package
Carton
Specification
1500*500*450mm
Trademark
JUGE or OEM
Origin
Nanjing, China

Product Description

Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor
Product Description
Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor

>>Application

This method is applicable to wastewater containing ammonia nitrogen within the range of 0-300 mg/L. Excessive calcium and magnesium ions, residual chlorine, turbidity, or other interfering factors may affect the measurement accuracy.


>>Technical parameters

1. Measurement Method: Nessler's spectrophotometric method
2. Measurement Range: 0-300 mg/L
3. Indication Error: ≤±3% when ≥5.00 mg/L; ≤±5% when <5.00 mg/L
4. Repeatability: ≤±2%
5. Measurement Cycle: Minimum cycle is 20 minutes; color development time can be adjusted flexibly between 5-30 min based on environmental conditions.
6. Sampling Cycle: Adjustable time interval (10-9999 min) or on-the-hour measurement mode.
7. Calibration Cycle: Adjustable at any interval from 1-99 days.
8. Maintenance Cycle: ≥168 hours, with each maintenance lasting ~1 hour.
9. Reagent Consumption: <0.50 CNY per sample.
10. Outputs: RS-232, 4mA-20mA, RS-485.
11. Environmental Requirements: Temperature-controlled indoor environment (recommended: 5-40°C); humidity 45%-85%.
12. Power Supply: AC 220±10% V, 50±1% Hz, 5A.
13. Dimensions: Height 1500 × Width 500 × Depth 450 mm.
14. Additional Features:

  • Data retention during abnormal alarms or power outages.
  • Touchscreen display and command input.
  • Automatic discharge of residual reactants and resumption of operation after power restoration or system reset.

>>Feature

Unique Design: This product features a distinctive design that ensures lower failure rates, reduced maintenance requirements, minimal reagent consumption, and higher cost-effectiveness compared to similar products.

  1. Selector Valve Assembly:

    • Enables flexible reagent sampling timing and diverse channel configurations.
    • Minimizes dead volume for easy maintenance and extended service life.
  2. Micro-Dosing Unit:

    • Utilizes a visual photoelectric system for precise reagent measurement, eliminating quantitative errors caused by peristaltic pump tube wear.
    • Achieves accurate micro-dosing with 0.7 mL per dose, significantly reducing reagent usage.
  3. Sample Introduction Unit:

    • Employs a peristaltic pump with negative pressure suction, creating an air buffer zone between reagents and the pump tube to prevent corrosion.
    • Simplifies and enhances flexibility in reagent mixing.
  4. Sealed Digestion Unit:

    • Operates under high-temperature and high-pressure conditions to accelerate reactions.
    • Eliminates corrosion risks from volatile gases in open systems.
  5. Reagent Tubing:

    • Uses imported modified PTFE (polytetrafluoroethylene) transparent tubing with an inner diameter >1.5 mm to minimize clogging by particulate matter in water samples.

>>Analytical Principle
After the water sample is mixed with a masking agent, ammonia nitrogen (present as free ammonia or ammonium ions) reacts with a salicylic acid chromogenic reagent under alkaline conditions and in the presence of a sensitizing agent, forming a colored complex. The analyzer detects this color change, converts it into an ammonia nitrogen concentration value, and outputs the result. The amount of colored complex formed corresponds to the concentration of ammonia nitrogen.
 
Company Profile

Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor
>>OEM Solutions & Service Advantages
We provide OEM customization services. Contact us to discuss tailored product solutions. 

1) 12-hour response guarantee for all inquiries;
2) Premium quality with industry-competitive pricing;
3) Dedicated post-purchase support system;
4) OEM/ODM compatibility;
5) Certified safety equipment specialists with expert engineering team.

 

>>FAQ
Q: Can I request a single sample unit for quality assessment?
A: Absolutely. We strongly advise sample evaluation before mass ordering.

 

Q: Could I obtain your product catalog and MOQ pricing details?
A: Our complete product portfolio is available digitally. Please browse our website for model specifications or email specific requests.

 

Q: What pricing advantages apply for large quantity orders?
A: Submit your complete requirements (product model, quantities, quality standards, branding specifications, payment terms, and logistics details) for optimized bulk pricing.

 

>>Certifications
Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor>>Shipping
Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online Automatic Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier